Airworthiness Directive · Amendment 39-23059 · Flight controls
Bombardier Inc. Airplanes
This AD applies to Bombardier Inc. Model BD-700-1A10 and BD-700-1A11 airplanes, certificated in any category, having serial numbers 9002 through 60086 inclusive, 60088 through 60091 inclusive, 60098, 60100, 60105, 60107, and 60111.
The FAA is adopting a new airworthiness directive (AD) for certain Bombardier Inc. Model BD-700-1A10 and BD-700-1A11 airplanes. This AD was prompted by a report that incorrect information was found in certain calculation tables in a section of the airplane flight manual (AFM) that addresses certain slat-flap conditions. This AD requires revising the Non-Normal Procedures section of the existing AFM to provide the flightcrew with corrected procedures to use in certain slat-flap conditions. The FAA is issuing this AD to address the unsafe condition on these products.
Within 30 days after the effective date of this AD, revise the existing AFM to incorporate the information in the applicable sections of the applicable AFMs identified in table 1 to paragraph (g) of this AD.
| Bombardier airplane model (marketing designation) | AFM | AFM section | AFM supplement, if applicable | AFM revision and issue date |
|---|---|---|---|---|
| BD-700-1A10 (Global Express) | Bombardier Global Express AFM, Publication No. CSP 700-1 1 | Jammed or Inoperative Slat/Flap Control Lever Procedure and Slat-Flap Fail (Caution) procedure, Slat and Flap Control Systems subsection, Section 05-10 Flight Controls, of Chapter 5—Non-Normal Procedures | Jammed or Inoperative Slat/Flap Control Lever procedure and Slat-Flap Fail procedure, Landing Distance Factors subsection of Non-Normal Procedures section of Chapter 7—Supplement 20—Operations at Airport Elevations Above 10,000 Feet | Revision 119, dated May 22, 2024. |
| BD-700-1A10 (Global Express XRS) | Bombardier Global Express AFM, Publication No. CSP 700-1A 2 | Jammed or Inoperative Slat/Flap Control Lever Procedure and Slat-Flap Fail (Caution) procedure, Slat and Flap Control Systems subsection, Section 05-10 Flight Controls, of Chapter 5—Non-Normal Procedures | Jammed or Inoperative Slat/Flap Control Lever procedure and Slat-Flap Fail procedure, Landing Distance Factors subsection of Non-Normal Procedures section of Chapter 7—Supplement 20—Operations at Airport Elevations Above 10,000 Feet | Revision 119, dated May 22, 2024. |
| BD-700-1A10 (Global 6000) | Bombardier Global 6000 AFM, Publication No. CSP 700-1V 3 | Jammed or Inoperative Slat/Flap Control Lever Procedure and Slat-Flap Fail (Caution) procedure, Slat and Flap Control Systems subsection, Section 05-10 Flight Controls, of Chapter 5—Non-Normal Procedures | Jammed or Inoperative Slat/Flap Control Lever procedure and Slat-Flap Fail procedure, Landing Distance Factors subsection of Non-Normal Procedures section of Chapter 7—Supplement 20—Operations at Airport Elevations Above 10,000 Feet | Revision 49, dated May 22, 2024. |
| BD-700-1A10 (Global 6500) | Bombardier Global 6500 AFM, Publication No. CSP-700-6500-1 4 | Jammed or Inoperative Slat/Flap Control Lever Procedure and Slat-Flap Fail (Caution) procedure, Slat and Flap Control Systems subsection, Section 05-10 Flight Controls, of Chapter 5—Non-Normal Procedures | None | Revision 21, dated May 22, 2024. |
| BD-700-1A11 (Global 5000) | Bombardier Global 5000 AFM, Publication No. CSP 700-5000-1 5 | Jammed or Inoperative Slat/Flap Control Lever Procedure and Slat-Flap Fail (Caution) procedure, Slat and Flap Control Systems subsection, Section 05-10 Flight Controls, of Chapter 5—Non-Normal Procedures | Jammed or Inoperative Slat/Flap Control Lever procedure and Slat-Flap Fail procedure, Landing Distance Factors subsection of Non-Normal Procedures section of Chapter 7—Supplement 20—Operations at Airport Elevations Above 10,000 Feet | Revision 80, dated May 22, 2024. |
| BD-700-1A11 (Global 5000 Featuring Global Vision Flight Deck) | Bombardier Global 5000 Featuring Global Vision Flight Deck AFM, Publication No. CSP 700-5000-1V 6 | Jammed or Inoperative Slat/Flap Control Lever Procedure and Slat-Flap Fail (Caution) procedure, Slat and Flap Control Systems subsection, Section 05-10 Flight Controls, of Chapter 5—Non-Normal Procedures | Jammed or Inoperative Slat/Flap Control Lever procedure and Slat-Flap Fail procedure, Landing Distance Factors subsection of Non-Normal Procedures section of Chapter 7—Supplement 20—Operations at Airport Elevations Above 10,000 Feet | Revision 49, dated May 22, 2024. |
| BD-700-1A11 (Global 5500) | Bombardier Global 5500 AFM, Publication No. CSP 700-5500-1 7 | Jammed or Inoperative Slat/Flap Control Lever Procedure and Slat-Flap Fail (Caution) procedure, Slat and Flap Control Systems subsection, Section 05-10 Flight Controls, of Chapter 5—Non-Normal Procedures | None | Revision 21, dated May 22, 2024. |
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, International Validation Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or responsible Flight Standards Office, as appropriate. If sending information directly to the manager of the International Validation Branch, send it to the attention of the person identified in paragraph (i) of this AD and email to: AMOC@faa.gov. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the responsible Flight Standards Office.
(2) Contacting the Manufacturer: For any requirement in this AD to obtain instructions from a manufacturer, the instructions must be accomplished using a method approved by the Manager, International Validation Branch, FAA; or Transport Canada; or Bombardier's Transport Canada Design Approval Organization (DAO). If approved by the DAO, the approval must include the DAO-authorized signature.
For more information about this AD, contact Gabriel Kim, Aviation Safety Engineer, FAA, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300; email 9-avs-nyaco-cos@faa.gov.