Airworthiness Directive · Amendment 39-22161 · Fire protection
Bombardier, Inc., Airplanes
This AD applies to Bombardier, Inc., Model BD-700-2A12 airplanes, certificated in any category, serial numbers (S/Ns) 70006 through 70044 inclusive, S/Ns 70046 through 70052 inclusive, and S/Ns 70055, 70056, and 70062.
The FAA is adopting a new airworthiness directive (AD) for certain Bombardier, Inc., Model BD-700-2A12 airplanes. This AD was prompted by a determination that the baggage bay line fire extinguishing tube assembly might not have been installed with the correct torque. This AD requires re-torqueing the baggage bay line fire extinguishing tube assembly to the correct torque values, and applying corrosion inhibiting compound on the discharge tubes. The FAA is issuing this AD to address the unsafe condition on these products.
Within 28 months after the effective date of this AD: Re-torque the baggage bay line fire extinguishing tube assembly to the correct torque values, and apply corrosion inhibiting compound on the discharge tubes, in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 700-26-7503, dated April 22, 2021.
Although Bombardier Service Bulletin 700-26-7503, dated April 22, 2021, specifies to submit certain information to the manufacturer, this AD does not include that requirement.
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, New York ACO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or responsible Flight Standards Office, as appropriate. If sending information directly to the manager of the certification office, send it to ATTN: Program Manager, Continuing Operational Safety, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the responsible Flight Standards Office.
(2) Contacting the Manufacturer: For any requirement in this AD to obtain instructions from a manufacturer, the instructions must be accomplished using a method approved by the Manager, New York ACO Branch, FAA; or Transport Canada Civil Aviation (TCCA); or Bombardier, Inc.'s TCCA Design Approval Organization (DAO). If approved by the DAO, the approval must include the DAO-authorized signature.
(1) Refer to TCCA AD CF-2021-48, dated December 15, 2021, for related information. This TCCA AD may be found in the AD docket at regulations.gov by searching for and locating Docket No. FAA-2022-0687.
(2) For more information about this AD, contact Elizabeth Dowling, Aerospace Engineer, Mechanical Systems and Administrative Services Section, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300; email 9-avs-nyaco-cos@faa.gov.