Airworthiness Directive · Amendment 39-21766 · Powerplant system
Hélicoptères Guimbal Helicopters
This AD applies to Hélicoptères Guimbal (HG) Model Cabri G2 helicopters, certificated in any category, the following aluminum cooling fan (cooling fan) part number (P/N) installed:
(1) P/N G52-00-000,
(2) P/N G52-00-001 or P/N G52-04-100, if it is or has previously been mounted on a 12-hole engine pulley P/N G52-10-100 or P/N G52-10-101.
The FAA is adopting a new airworthiness directive (AD) for H[eacute]licopt[egrave]res Guimbal (HG) Model Cabri G2 helicopters with certain part-numbered aluminum cooling fans (cooling fan) installed. This AD was prompted by a report of an occurrence of an in-flight shutdown due to a crack and subsequent failure of the cooling fan. This AD requires removing certain part-numbered cooling fans from service, or modifying certain part-numbered cooling fans before exceeding a certain total hours time-in-service (TIS), and installing newly designed cooling fans. This AD also prohibits installing any affected cooling fan on any helicopter. The FAA is issuing this AD to address the unsafe condition on these products.
(1) For Model Cabri G2 helicopters with cooling fan P/N G52-00-000 installed, within 150 hours time-in-service (TIS) after the effective date of this AD:
(i) Remove the cooling fan from service by following the Required Actions, Cooling Fan Removal, paragraphs (a) through (g), of Guimbal Service Bulletin SB 16-021 E, dated August 27, 2019 (SB 16-021 Rev E), except you are not required to discard any parts.
(ii) Install the improved cooling fan P/N G52-04-101 by following the Required Actions, Cooling Fan Installation, paragraphs (a) through (j), of SB 16-021 Rev E.
(2) For Model Cabri G2 helicopters with a cooling fan P/N G52-00-001 or P/N G52-04-100 that is mounted or was previously mounted on a 12-hole engine pulley P/N G52-10-100 or P/N G52-10-101, and with 1,500 or more total hours TIS, since first installation on a helicopter, within 150 hours TIS after the effective date of this AD:
(i) Remove the cooling fan from service by following the Required Actions, Cooling Fan Removal, paragraphs (a) through (g), of SB 16-021 Rev E, except you are not required to discard any parts, or remove the cooling fan by following the Required Actions, Cooling Fan Removal, paragraphs (a) through (g), of SB 16-021 Rev E and modify the cooling fan by following the Required Actions, Cooling Fan Retrofit, paragraphs (a) through (h) of SB 16-021 Rev E.
(ii) Install the improved cooling fan P/N G52-04-101 by following the Required Actions, Cooling Fan Installation, paragraphs (a) through (j), of SB 16-021 Rev E.
(3) For Model Cabri G2 helicopters with a cooling fan P/N G52-00-001 or P/N G52-04-100 that is mounted or was previously mounted on a 12-hole engine pulley P/N G52-10-100 or P/N G52-10-101 and with 500 total hours TIS but with less than 1,500 total hours TIS, since first installation on a helicopter, within 500 hours TIS after the effective date of this AD, perform the actions required by paragraphs (g)(2)(i) and (ii) of this AD.
(4) For Model Cabri G2 helicopters with a cooling fan P/N G52-00-001 or P/N G52-04-100 that is mounted or was previously mounted on a 12-hole engine pulley P/N G52-10-100 or P/N G52-10-101 and with less than 500 total hours TIS since first installation on a helicopter, within 1,000 hours TIS after the effective date of this AD, perform the actions required by paragraphs (g)(2)(i) and (ii) of this AD.
(5) As of the effective date of this AD, do not install any cooling fan listed in paragraph (c) of this AD on any helicopter.