Airworthiness Directive · Amendment 39-17756 · Fuselage
the Boeing Company Airplanes
This AD applies to the Boeing Company Model 737-600, -700, -800, -900, and -900ER series airplanes, certificated in any category, with Live TV radomes having part number 5063-100-V3 or 5063-101-V2 and a serial number in the range of 001 through 497 inclusive, and modified by the applicable supplemental type certificate (STC) identified in paragraphs (c)(1) and (c)(2) of this AD.
(1) ST00284BO (http://rgl.faa.gov/Regulatory_and_Guidance_Library/rgstc.nsf/0/3ecc2e5e5f408bc1862579b30048ed60/$FILE/ST00284BO.pdf).
(2) ST02887AT (http://rgl.faa.gov/Regulatory_and_Guidance_Library/rgstc.nsf/0/9bf85b85ea3e295d8625735600721055/$FILE/ST02887AT.pdf).
We are adopting a new airworthiness directive (AD) for certain The Boeing Company Model 737-600, -700, -800, -900, and -900ER series airplanes modified by particular supplemental type certificates (STCs). This AD was prompted by reports of cracks found during inspections of the in-flight entertainment system radome assembly. This AD requires repetitive detailed inspections for cracks in the radome assembly, and replacement of the radome if necessary. We are issuing this AD to detect and correct cracks in the in-flight entertainment system radome assembly, which could result in the radome (or pieces) separating from the airplane and striking the tail, and consequently reducing the controllability of the airplane.
Within 1,250 flight hours after the effective date of this AD: Perform a detailed inspection for cracks of the radome assembly, in accordance with the Accomplishment Instructions of Live TV Service Bulletin B737-53-0011, dated March 29, 2013. Repeat the inspection thereafter at intervals not to exceed 1,250 flight hours. If any crack is found during any inspection required by this paragraph, before further flight, replace the radome, in accordance with the Accomplishment Instructions of Live TV Service Bulletin B737-53-0011, dated March 29, 2013.
If any crack is found during any inspection required by paragraph (g) of this AD, submit a report of the findings to Live TV, 8900 Hangar Boulevard, Orlando, FL 32827; phone: 407-812-2600; fax: 407-812-2526; email JaneAnne.Webb@livetv.net; at the applicable time specified in paragraph (h)(1) or (h)(2) of this AD. The report must include the information specified in the service bulletin reporting form provided in Live TV Service Bulletin B737-53-0011, dated March 29, 2013.
(1) If the inspection was accomplished on or after the effective date of this AD: Submit the report within 30 days after the inspection.