Airworthiness Directive · Amendment 39-17314 · Turbomeca S.A. Turboshaft Engines
Turbomeca S.A. Turboshaft Engines
This AD applies to all Turbomeca S.A. ARRIEL 1A1, 1A2, 1B, 1C, 1C1, 1C2, 1D, 1D1, 1E2, 1K1, 1S, and 1S1 turboshaft engines.
We are adopting a new airworthiness directive (AD) for all Turbomeca S.A. Arriel 1A1, 1A2, 1B, 1C, 1C1, 1C2, 1D, 1D1, 1E2, 1K1, 1S, and 1S1 turboshaft engines. This AD requires performing a high gas generator speed (NG) rating vibration check. This AD was prompted by several reports of uncommanded in-flight shutdown on Arriel 1 engines. We are issuing this AD to prevent an uncommanded in- flight shutdown of the engine, which could result in an emergency landing.
Unless already done, from the effective date of this AD, do the following. After any Level 3 maintenance action on the gas generator (GG) rotating assembly and before returning the engine to service, accomplish a high GG speed (NG) rating vibration check.
Level 3 maintenance on the GG rotating assembly is when the Module 03 is removed from the helicopter for implementation of deep maintenance operation to be performed in accordance with the applicable maintenance instructions.
The aircraft, engines and makers this AD names, by the model designations in its text. A model listed here may still be outside the AD's serial ranges.