Airworthiness Directive · Amendment 39-15817 · Flight controls
Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes
Superseded. A later AD replaced this one: AD 2010-08-03. Comply with the one in force.
This AD applies to Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, serial number 7003 and subsequent, certificated in any category, that are equipped with Thales angle of attack (AOA) transducers having part number 45150340 or C16258AA.
We are adopting a new airworthiness directive (AD) for the products listed above. This AD results from mandatory continuing airworthiness information (MCAI) originated by an aviation authority of another country to identify and correct an unsafe condition on an aviation product. The MCAI describes the unsafe condition as:
Unless already done, do the following actions:
(1) For airplanes equipped with a transducer having accumulated more than 7,500 total flight hours as of the effective date of this AD: Within 250 flight hours after the effective date of this AD, measure the inrush current of both AOA transducers in accordance with Part A of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008.
(i) If both AOA transducers are found to have an inrush current of 1.60 amps or more, repeat the measurement thereafter at intervals not to exceed the applicable interval specified in Table 1 of this AD. Do the measurement in accordance with Part A of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008.
| If the last inrush current measurement of the serviceable AOA transducer is— | Then repeat the measurement— |
|---|---|
| More than or equal to 1.90 amps | Within 2,000 flight hours after the last measurement. |
| More than or equal to 1.80 amps but less than 1.90 amps | Within 1,500 flight hours after the last measurement. |
| More than or equal to 1.70 amps but less than 1.80 amps | Within 1,000 flight hours after the last measurement. |
| More than or equal to 1.60 amps but less than 1.70 amps | Within 500 flight hours after the last measurement. |
(ii) If one AOA transducer is found to have an inrush current below 1.60 amps, and the other AOA transducer is found to have an inrush current of 1.60 amps or more: Do the actions required by paragraphs (f)(1)(ii)(A) and (f)(1)(ii)(B) of this AD.
(A) For the AOA transducer having an inrush current of 1.60 amps or more: Repeat the measurement thereafter at intervals not to exceed the applicable interval specified in Table 1 of this AD. Do the measurement in accordance with Part A of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008.
(B) For the AOA transducer having an inrush current below 1.60 amps (“degraded” transducer): Within 1,000 flight hours after the effective date of this AD, replace that transducer in accordance with Part C of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008. At the applicable time specified in Table 1 of this AD if the degraded transducer was replaced with a serviceable transducer, or within 2,000 flight hours after replacement if the degraded transducer was replaced with a new transducer, do the measurement for that replacement transducer and repeat the measurements thereafter at intervals not to exceed the applicable interval specified in Table 1 of this AD. Do the measurement in accordance with Part A of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008.
(iii) If both AOA transducers are found to have an inrush current below 1.60 amps, do the action specified in paragraph (f)(1)(iii)(A) or (f)(1)(iii)(B) of this AD.
(A) Before further flight, replace one of the degraded AOA transducers with a new or serviceable transducer; and replace the other degraded transducer with a new or serviceable transducer within 1,000 flight hours after the measurement required by paragraph (f)(1) of this AD; in accordance with Part C of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008. At the applicable time specified in Table 1 of this AD, if the degraded transducer was replaced with a serviceable transducer; or within 2,000 flight hours after replacement if the degraded transducer was replaced with a new transducer: Do the measurement for that replacement transducer and repeat the measurement thereafter at intervals not to exceed the applicable interval specified in Table 1 of this AD. Do the measurements in accordance with Part A of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008.
(B) Within 1,000 flight hours after the measurement required by paragraph (f) of this AD, replace both degraded AOA transducers with new or serviceable transducers in accordance with Part C of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008. Until the replacement is done, dispatch with two degraded AOA transducers is allowed, provided that the applicable Limitations section of the airplane flight manual (AFM) is revised to include the following statement or a copy of this AD is inserted into the applicable Limitations section of the AFM.
“Dispatch is allowed if:
(a) Operations are not conducted in visible moisture (including standing water and slush) in any form,
(b) Operations are not conducted in known or forecast icing conditions,
(c) Both Ice Detection Systems are operative; and,
(d) Operations are conducted in day VMC conditions only.”
After the replacement has been accomplished, the statement or the copy of this AD may be removed from the AFM. At the applicable time specified in Table 1 of this AD, if the degraded transducer was replaced with a serviceable transducer; or within 2,000 flight hours after replacement with a new transducer: Do the measurement for that replacement transducer and repeat the measurement thereafter at intervals not to exceed the applicable interval specified in Table 1 of this AD. Do the measurement in accordance with Part A of Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008.
(2) If, during any repetitive measurement required by paragraphs (f)(1)(i), (f)(1)(ii), and (f)(1)(iii) of this AD, any AOA transducer is found to have an inrush current below 1.60 amps, before further flight, replace that transducer in accordance with Part C of the Accomplishment Instructions of Bombardier Service Bulletin 601R-27-153, Revision A, dated December 16, 2008. At the applicable time specified in Table 1 of this AD, if the degraded transducer was replaced with a serviceable transducer; or within 2,000 flight hours after replacement if the degraded transducer was replaced with a new transducer: Do the measurement for that replacement transducer as specified in paragraph (f)(1)(ii)(B) of this AD and repeat the measurement thereafter at intervals not to exceed the applicable interval specified in Table 1 of this AD.
(3) Actions done before the effective date of this AD in accordance with Bombardier Service Bulletin 601R-27-153, dated October 17, 2008, are acceptable for compliance with the corresponding requirements of paragraphs (f)(1) and (f)(2) of this AD.
Note 1: This AD differs from the MCAI and/or service information as follows: This AD does not require the following actions specified in the MCAI: the one-time inspection for serial numbers and on-condition replacement in Paragraph 1. of the MCAI, and the initial inspection compliance times for transducers with 7,500 or fewer flight hours as of the effective date of this AD in Paragraph 2. of the MCAI. The planned compliance times for those actions would allow enough time to provide notice and opportunity for prior public comment on the merits of those actions. Therefore, we are considering further rulemaking to address this issue.
The aircraft, engines and makers this AD names, by the model designations in its text. A model listed here may still be outside the AD's serial ranges.