Airworthiness Directive · Amendment 39-15580 · Hawker Beechcraft Corporation (Type Certificates No. 3A15, No. 3A16, No. A23CE, and No. A30CE Previously Held by Raytheon Aircraft Company) F33 Series and Models G33, V35B, A36, A36TC, B36TC, 95-B55, D55, E55, A56TC, 58, 58P, 58TC, G58, and 77 Airplanes
Hawker Beechcraft Corporation (Type Certificates No. 3A15, No. 3A16, No. A23CE, and No. A30CE Previously Held by Raytheon Aircraft Company) F33 Series and Models G33, V35B, A36, A36TC, B36TC, 95-B55, D55, E55, A56TC, 58, 58P, 58TC, G58, and 77 Airplanes
This AD applies to the following airplane models and serial numbers that have a part number (P/N) 35-380132-1 through 35-380132-53 circuit breaker toggle switch installed and are certificated in any category:
| Models | Serial Nos. |
|---|---|
| (1) F33 and G33 | CD-1235 through CD-1304. |
| (2) F33A | CE-290 through CE-1791. |
| (3) F33C | CJ-26 through CJ-179. |
| (4) V35B | D-9069 through D-10403. |
| (5) A36 | E-185 through E-3629 and E-3631 through E-3635. |
| (6) A36TC and B36TC | EA-1 through EA-695. |
| (7) 95-B55 | TC-1913, TC-1936 through TC-2456. |
| (8) D55 | TE-452 through TE-767. |
| (9) E55 | TE-768 through TE-1201. |
| (10) A56TC | TG-84 through TG-94. |
| (11) 58 | TH-1 through TH-2124. |
| (12) 58P | TJ-3 through TJ-497. |
| (13) 58TC | TK-1 through TK-151. |
| (14) G58 | TH-2126, TH-2127, TH-2131 through TH-2134, TH-2136, TH-2137, TH-2139 through TH-2141, and TH-2143 through TH-2150. |
| (15) 77 | WA-1 through WA-312. |
The FAA adopts a new airworthiness directive (AD) for certain Hawker Beechcraft Corporation F33 series and Models G33, V35B, A36, A36TC, B36TC, 95-B55, D55, E55, A56TC, 58, 58P, 58TC, G58, and 77 airplanes. This AD requires you to replace certain circuit breaker toggle switches with improved design circuit breaker toggle switches. This AD results from reports of certain circuit breaker toggle switches used in various electrical systems throughout the affected airplanes overheating. We are issuing this AD to prevent failure of the circuit breaker toggle switch, which could result in smoke in the cockpit and the inability to turn off the switch.
To address this problem, you must do the following, unless already done:
| Actions | Compliance | Procedures |
|---|---|---|
| (1) Replace all affected circuit breaker toggle switches specified in paragraph (c) of this AD with an improved circuit breaker toggle switch, P/N 35-380132-61 through 35-380132-113, as applicable | Within the next 12 months after August 6, 2008 (the effective date of this AD) | As specified in Hawker Beechcraft Recommended Service Bulletin SB 24-3807, Issued: May 2007, and Raytheon Aircraft Company Recommended Service Bulletin SB 24-3735, Issued: August 2005. |
| (2) Do not install a circuit breaker toggle switch specified in paragraph (c) of this AD | Before further flight after the replacement required by paragraph (e)(1) of this AD | Not applicable. |
The aircraft, engines and makers this AD names, by the model designations in its text. A model listed here may still be outside the AD's serial ranges.