Airworthiness Directive · Amendment 39-15177 · McDonnell Douglas Model MD-90-30 Airplanes
McDonnell Douglas Model MD-90-30 Airplanes
Model MD-90-30 airplanes, certificated in any category, as identified in Boeing Service Bulletin MD90-30-026, Revision 1, dated May 27, 2005.
This amendment adopts a new airworthiness directive (AD), applicable to certain McDonnell Douglas Model MD-90-30 airplanes, that requires repetitive inspections and functional tests of the static port heater assemblies, and corrective actions if necessary. The actions specified by this AD are intended to prevent an electrical short of the static port heater from sparking and igniting the insulation blanket adjacent to the static port heater, which could result in smoke and/or fire in the cabin area. This action is intended to address the identified unsafe condition.
To prevent an electrical short of the static port heater from sparking and igniting the insulation blanket adjacent to the static port heater, which could result in smoke and/or fire in the cabin area, accomplish the following:
(a) The term “service bulletin,” as used in this AD, means the Accomplishment Instructions of Boeing Service Bulletin MD90-30-026, Revision 1, dated May 27, 2005.
(b) Within 18 months after the effective date of this AD, perform a general visual inspection of the left and right primary and alternate static port heater assemblies for wire damage; and perform a functional test of the left and right primary and alternate static port heater assemblies; in accordance with the service bulletin. Repeat the actions thereafter at intervals not to exceed 48 months.
Note 1: For the purposes of this AD, a general visual inspection is: “A visual examination of an interior or exterior area, installation or assembly to detect obvious damage, failure or irregularity. This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to ensure visual access to all surfaces in the inspection area. This level of inspection is made under normal available lighting conditions such as daylight, hangar lighting, flashlight or drop-light and may require removal or opening of access panels or doors. Stands, ladders or platforms may be required to gain proximity to the area being checked.”
(c) If wire damage is found and/or the heater assembly fails the functional test during the general visual inspection and functional test required by paragraph (b) of this AD: Before further flight, replace the damaged or inoperative static port heater assembly with a new or serviceable static port heater assembly in accordance with the service bulletin.
(d) Actions accomplished before the effective date of this AD according to Boeing Service Bulletin MD90-30-026, dated February 15, 2002, are considered acceptable for compliance with the corresponding actions specified in this AD.
(e)(1) In accordance with 14 CFR 39.19, the Manager, Los Angeles Aircraft Certification Office (ACO), is authorized to approve alternative methods of compliance for this AD.
(2) To request a different method of compliance or a different compliance time for this AD, follow the procedures in 14 CFR 39.19. Before using any approved AMOC on any airplane to which the AMOC applies, notify your appropriate principal inspector (PI) in the FAA Flight Standards District Office (FSDO), or lacking a PI, your local FSDO.
(f) Unless otherwise specified in this AD, the actions must be done in accordance with Boeing Service Bulletin MD90-30-026, Revision 1, dated May 27, 2005. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. To get copies of this service information, contact Boeing Commercial Airplanes, Long Beach Division, 3855 Lakewood Boulevard, Long Beach, California 90846, Attention: Data and Service Management, Dept. C1-L5A (D800-0024). To inspect copies of this service information, go to the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, Washington; or to the FAA, Los Angeles Aircraft Certification Office, 3960 Paramount Boulevard, Lakewood, California; or to the National Archives and Records Administration (NARA). For information on the availability of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.