Airworthiness Directive · Amendment 39-14202 · Rolls-Royce plc RB211-524 Series Turbofan Engines
Rolls-Royce plc RB211-524 Series Turbofan Engines
Superseded. A later AD replaced this one: AD 2007-06-10. Comply with the one in force.
This AD applies to the Rolls-Royce plc (RR) RB211-524 series turbofan engines listed in the following Table 1, with intermediate pressure (IP) compressor stage 5 disk part numbers (P/Ns) listed in Table 2 of this AD, installed.
| −524B-02 | −524B-B-02 | −524B3-02 | −524B4-02 | −524B4-D-02 |
| −524B2-19 | −524B2-B-19 | −524C2-19 | −524C2-B-19 | −524D4-19 |
| −524D4-B-19 | −524D4X-19 | −524D4X-B-19 | −524D4-39 | −524D4-B-39 |
| −524G2-19 | −524G2-T-19 | −524G3-19 | −524G3-T-19 | −524H2-19 |
| −524H2-T-19 | −524H-36 | −524H-T-36 |
These engines are installed on, but not limited to, Boeing 747, 767, and Lockheed L-1011 airplanes.
| LK60130 | LK65932 | LK69021 | LK81269 | LK83282 |
| LK83283 | UL12290 | UL15743 | UL15744 | UL15745 |
| UL19132 | UL20785 | UL20832 | UL23291 | UL25011 |
| UL36821 | UL36977 | UL36978 | UL36979 | UL36980 |
| UL36981 | UL36982 | UL36983 | UL37078 | UL37079 |
| UL37080 | UL37081 | UL37082 | UL37083 | UL37084 |
The FAA is adopting a new airworthiness directive (AD) for Rolls Royce plc (RR) RB211-524 series turbofan engines with certain part number (P/N) intermediate pressure (IP) compressor stage 5 disks installed. This AD requires new reduced IP compressor stage 5 disk cyclic limits. This AD also requires removing from service affected disks that already exceed the new reduced cyclic limit, and removing other affected disks before exceeding their cyclic limits, using a drawdown schedule. This AD results from the discovery of cracks in the cooling air hole areas of the disk front spacer arm. We are issuing this AD to prevent IP compressor stage 5 disk failure, which could result in uncontained engine failure and possible damage to the airplane.
You are responsible for having the actions required by this AD performed within the compliance times specified unless the actions have already been done.
Change the service cyclic limits contained in the Time Limits Manual, 05-10-01, for the IP compressor stage 5 discs installed in the engine models listed in the following Table 3, within 30 days after the effective date of this AD.
| Engine models | -524G2, G2-T, G3, G3-T, H2, H2-T, H-36, H-T-36 | -524D4, D4-B, D4-B-39, D4X, D4X-B, D4-39 CIS | -524B2, B2-B, C2, C2-B CIS | -524B-02, B-B-02, B3-02, B4-02, B4-D-02 CIS |
|---|---|---|---|---|
| November 30, 2002 | 13,500 cycles-in-service (CIS) | 16,150 | 16,000 | 16,200 |
| April 1, 2003 | 13,500 CIS | 13,500 | 13,500 | 14,000 |
| December 1, 2003 | 12,000 CIS | 13,500 | 13,500 | 14,000 |
| December 1, 2004 | 11,000 CIS | 13,500 | 12,000 | 12,000 |
| December 1, 2005 | 11,000 CIS | 12,000 | 12,000 | 12,000 |
| December 1, 2008 | 7,830 CIS | 8,700 | 8,900 | 9,000 |
Before December 1, 2008, optional inspections are allowed at each shop visit or on-wing to extend the disk life. Guidance for these inspections is provided in paragraphs (h) or (i) of this AD.
Perform optional inspections at shop visit, as follows:
(1) Remove corrosion protection from IP stage 5 disk. Information on corrosion protection removal can be found in the Engine Manual.
(2) Visual-inspect and binocular-inspect the IP stage 5 disk for corrosion pitting at the cooling air holes and defender holes in the disk front spacer arm. Follow paragraph 3.C. of the Accomplishment Instructions of RR MSB No. RB.211-72-D428, Revision 3, dated June 30, 2003. Information on disk corrosion pitting limits can be found in the Engine Manual.
(i) If the disk has corrosion pitting in excess of limits, remove the disk from service.
(ii) If the disk is free from corrosion pitting, MPI the entire disk. Information on MPI can be found in the Engine Manual. If the disk passes MPI and no cracks are found, complete all other inspections, re-apply corrosion protection to disk, and return the disk to service in accordance with the cyclic limits allowed by paragraph (k) of this AD. Information on MPI limits can be found in the Engine Manual. Information on re-applying corrosion protection can be found in RR Repair FRS5900.
(iii) If the disk has corrosion pitting within limits, ECI all disk cooling air holes, defender holes, and inner and outer faces. Follow paragraph 3.D. of the Accomplishment Instructions of RR MSB No. RB.211-72-D428, Revision 3, dated June 30, 2003. Information on corrosion pitting limits can be found in the Engine Manual. If the disk passes ECI and no cracks are found, MPI the entire disk. Information on MPI can be found in the Engine Manual. If the disk passes MPI and no cracks are found, re-apply corrosion protection to disk, and return the disk to service in accordance with the cyclic limits allowed by paragraph (k) of this AD.
(i) For RB211-524B2/C2 and RB211-524B4/D4 engine models, an on-wing ECI of the IP compressor stage 5 disk may be performed only once between shop visit inspections. Follow paragraphs 3.A. through 3.F. of the Accomplishment Instructions of RR SB No. RB.211-72-E148, dated March 13, 2003, and RR SB No. RB.211-72-E150, Revision 1, dated June 4, 2003, respectively, to do the ECI. If the disk passes the ECI and no cracks are found, an extension is allowed as specified in paragraph (k) of this AD.
For the purposes of this AD, a shop visit is defined as the separation of an engine major case flange. This definition excludes shop visits when only field maintenance type activities are performed in lieu of performing them on-wing. (i.e., for purposes such as to perform an on-wing inspection of a tail engine installation on a Lockheed L-1011 airplane).
Disks that pass an optional inspection may remain in service after that inspection for the additional cycles listed in the following Table 4, until the next inspection, or December 1, 2008, or until the cyclic life limit published in the Time Limits Manual is reached, whichever occurs first.
| Engine models | -524G2, G2-T, G3, G3-T, H2, H2-T, H-36, H-T-36 (cycles) | -524D4, D4-B, D4-B-39, D4X, D4X-B, D4-39 (cycles) | -524B2, B2-B, C2, C2-B (cycles) | -524B-02, B-B-02, B3-02, B4-02, B4-D-02 (cycles) |
|---|---|---|---|---|
| Extension After Passing MPI | 1,600 | 2,000 | 2,000 | 2,000 |
| Extension After Passin In-Shop ECI | 3,800 | 4,500 | 4,500 | 4,500 |
| Extension After Passing On-Wing ECI | 1,000 | 1,200 | 1,200 | 1,200 |
Information on intermixing disks between engine models can be found in the RR Time Limits Manual, 05-00-01.
The aircraft, engines and makers this AD names, by the model designations in its text. A model listed here may still be outside the AD's serial ranges.
Engines